Can External Wall Insulation Go On in a Dublin Winter? What the Agrément Certificates Say About Temperature
Can External Wall Insulation Go On in a Dublin Winter? What the Agrément Certificates Say About Temperature
External wall insulation has a temperature limit written into its certificate. In the two certificates we read for this post, the adhesive, base coat and render must not be applied below 5°C, and the finish then has to stay above a set temperature for the next two to three days. That is the real answer to the question we hear most in November from people weighing up external wall insulation Dublin installers are quoting for: can the wrap go on now, or does it wait for spring?
The short version is that the paperwork can start today and the wet work goes on when the forecast allows. Here is where the limits come from, so you can ask any installer the right questions.
What the certificate says about applying the coats
SEAI’s homeowner’s guide to wall insulation says your contractor must use an NSAI Agrément certified product or equivalent, and must be NSAI registered to install it. The certificate is not a brochure. It is the instruction sheet the installer is bound to, and it includes weather limits.
The Ceresit Ceretherm certificate and the Soltherm certificate agree on the basics. Adhesives, base coats, primers and finish coats must not be applied below 5°C or above 25°C. Until the coatings are fully cured they must be protected from rapid drying, rain, direct sun and strong wind.
Both certificates also name exceptions. Ceresit lists two products approved for use outside that range, and Soltherm lists a base coat that can go on at 0°C and above, plus a winter additive. Those exceptions belong to those systems. They are not a general licence to render in a frost, so it is worth asking which product is going on your house.
The number people miss is the curing window
Application temperature is one number. The second matters more in Dublin, because it looks forward. Both certificates set a minimum temperature for the days after a coat goes on:
| Finish coat | Ceresit Ceretherm | Soltherm |
|---|---|---|
| Applying any coat | 5°C to 25°C (unless an approved low-temperature product is used) | 5°C to 25°C (unless an approved low-temperature product is used) |
| Cement-free, synthetic-resin or silicone-resin finish | Not below 5°C for 72 hours after | Not below 5°C for 48 hours after |
| Silicate finish | Not below 8°C for 72 hours after | Not below 10°C for 48 hours after |
That means a bright, dry 7°C afternoon is not automatically a render day. If the forecast shows a frost on the second night, a careful installer holds the finish coat back. The certificate for the system on your own house is the one that counts, so ask to see it.
What that does to a winter job
Everything wet on an external wall insulation job sits inside these limits: the adhesive that holds the boards, the base coat that carries the mesh, the primer and the finish. A cold, wet fortnight can therefore move a stage, even when the scaffold is already up.
A pause for weather is the installer following the certificate, not stalling. What you should expect to see is covers on work that has not cured, and a plain explanation of which stage is waiting for which forecast. Met Éireann’s Dublin forecast is the same one the installer should be reading, and it is worth glancing at it yourself before you book a start date.
Our walk-through of what happens on an external wall insulation job from survey to sign-off shows where each of those wet stages falls.
What can move now, whatever the weather
None of the early steps need a dry, mild day.
The first is the survey. SEAI’s guide says the first step is establishing your wall type: cavity, solid or hollow block. That decides whether external wall insulation is even the right measure for your house.
The second is the grant. SEAI’s fixed wall insulation grants currently run from €700 for a cavity fill in an apartment to €8,000 for external wall insulation on a detached house. You need the grant offer before work starts. Once you receive it you have 30 days to accept, and eight months from the date of the offer to finish the work and draw down the grant. An offer dated in November therefore runs into the following July, which leaves room for a dry spell.
The third is anything that involves another party. SEAI’s guide notes that external wall insulation may need planning permission in some cases, and it may need an ESB Networks service alteration, where fees may apply. The ESB Networks service alteration is a separate process from the building work, so it is better settled before the scaffold goes up than during the job.
Does cavity fill have the same limit?
Much less so. Cavity wall insulation is injected from the outside into the gap between the two leaves of masonry, so there is no render system and no multi-day coating cure to protect. The question for cavity walls is whether your walls are suitable at all, which is why the survey comes first. Hollow block, for example, is not a cavity wall, however much it looks like one.
Five questions to put to any installer
- Which NSAI Agrément certified system will go on my house, and can I see the certificate?
- What are its minimum application temperature and its curing-window temperature for the finish I have chosen?
- What do you do to protect uncured work if the forecast turns?
- Who tells me when weather has moved a stage, and by how long?
- Who is dealing with the ESB Networks service alteration and the planning check?
The NSAI homeowner leaflet on external wall insulation covers the certificate and approved-installer questions in plain English, and it is a useful read before you compare quotes.
We do home energy upgrades across Dublin, including walls. Call us on 01-233-7477, or Claim Your Grants for external wall insulation and we will book your free survey.
Claim Your Grants
See your grant figure